top of page


Detached House / 3 BED + STUDY

 

Wellbuild offers a turn-key service. This means that we manage all aspects of the interior of your new home – except the kitchen. This is because there are so many choices of kitchen that we prefer to leave the kitchen and its installation up to you.

 

 

 

Scope of work

  • Design

  • Turning off and disconnecting supply (water, heating, power)

  • Ripping out (toilet, sink, bath, boxing, tiles)

  • Removal of old suite and waste

  • Plumbing (pipework adjustments, toilet cistern frame installation)

  • Electrical work (extractor fan, ceiling lights, light switch, mirror light, heated towel rail, earth cable)

  • Dry lining walls & tile backer boards (Abacus elements backer board kit)

  • Bath boxing

  • Waterproofing membrane

  • Wall tiling 600x600 70no.

  • Floor tiling 600x600 15no.

  • Toilet installation (toilet, seat, flush plate, toilet roll holder, wall mounted toilet brush)

  • Basin installation (basin, tap, van unit, towel rail, mirror)

  • Bath installation (bath, tap, enclosure)

  • Heated towel rail installation

  • Door installation

  • Removal of waste

  • Finishing (ceiling painting)

Drawings PDF   |   KIT specification   |   Externally finished specification   |   Complete build specification


Construction Type  E1
External Wall

E1.jpg
BBA logo.jpeg

  • 20mm brick slips

  • Brictec tracker board 12mm

  • DPC membrane

  • Timber counter battens 40x60@600mm

  • Fermacell 15mm H2O board

  • Timber structure 120x60/120@600mm

  • Insulation 120mm (Mineral)

  • VCL membrane

  • Timber counter battens 40x60@600mm

  • Insulation 40mm (Mineral)

  • Fermacell 15mm board

  • 3mm skim (not included)


Construction Type  E3
External Wall

  • 10mm horizontal weatherboarding (not included)

  • Timber counter battens 40x60@600mm

  • Breather membrane

  • Timber battens 60x40@600mm

  • Insulation 60mm (Mineral)

  • Fermacell 15mm board

  • Timber structure 120x60/120@600mm

  • Insulation 120mm (Mineral)

  • VCL membrane

  • Timber counter battens 40x60@600mm

  • Insulation 40mm (Mineral)

  • Fermacell 15mm board

  • 3mm skim (not included)

obvodová stěna s dřevěným obložením.jpg
BBA logo.jpeg


Construction Type  E4
External Wall

E4.jpg
BBA logo.jpeg

  • 3mm render (not included)

  • Glass meshwork and cement

  • Polystyrene 100mm and adhesive

  • Fermacell 15mm board

  • Timber structure 120x60/120@600mm

  • Insulation 120mm (Mineral)

  • VCL membrane

  • Timber counter battens 40x60@600mm

  • Insulation 40mm (Mineral)

  • Fermacell 15mm board

  • 3mm skim (not included)

 


Construction Type  E4b
External Wall

E4b.jpg
BBA logo.jpeg

  • 3mm render (not included)

  • Glass meshwork and cement

  • Polystyrene 100mm and adhesive

  • Fermacell 15mm board

  • Timber structure 120x60/120@600mm

  • Insulation 120mm (Mineral)

  • VCL membrane

  • Fermacell 15mm board

  • 3mm skim (not included)

 


Construction Type  E5
External Wall

E5.jpg
BBA logo.jpeg

  • 102.5mm brick or blockwork (not icluded)

  • 50mm clear cavity with flexibe wall ties, nailed to studs (not icluded)

  • Glidevale Protect TF200 Thermo Insulated breather membrane

  • Fermacell 15mm H2O board

  • Timber structure 120x60/120@600mm

  • Insulation 120mm (Mineral)

  • VCL membrane

  • Timber counter battens 40x60@600mm

  • Insulation 40mm (Mineral)

  • Fermacell 15mm board

  • 3mm skim (not included)


Construction Type  P1
Party Wall

P1.jpg
BBA logo.jpeg

  • Fermacell 15mm board

  • Timber structure 120x60/120@600mm

  • Insulation 120mm (Mineral)

  • VCL membrane

  • Fermacell 15mm board

  • 3mm skim (not included)


Construction Type  L1
Load Bearing Wall

L1.jpg
BBA logo.jpeg

  • 3mm skim (not included)

  • Fermacell 15mm board

  • Timber structure 120x60/120@600mm

  • Insulation 120mm (Mineral)

  • Fermacell 15mm board

  • 3mm skim (not included)


Construction Type  L2
Load Bearing Wall

L2.jpg
BBA logo.jpeg

  • 3mm skim (not included)

  • Fermacell 15mm board

  • Fermacell 15mm board

  • Timber structure 120x60/120@600mm

  • Insulation 120mm (Mineral)

  • Fermacell 15mm board

  • Fermacell 15mm board

  • 3mm skim (not included)


Construction Type  I1
Internal Wall

I1.jpg
BBA logo.jpeg

  • 3mm skim (not included)

  • Fermacell 15mm board

  • Timber structure 60x60/120@600mm

  • Insulation 50mm (Mineral)

  • Fermacell 15mm board

  • 3mm skim (not included)


Construction Type  I2
Internal Wall

I2.jpg
BBA logo.jpeg

  • 3mm skim (not included)

  • Fermacell 15mm board

  • Fermacell 15mm board

  • Timber structure 60x60/120@600mm

  • Insulation 50mm (Mineral)

  • Fermacell 15mm board

  • Fermacell 15mm board

  • 3mm skim (not included)


Construction Type  F0
Floor

C0.png

  • Precast hollowcore concrete plank (not included)L

 


Construction Type  F1
Floor

SCHÉMA STROPU NAD PŘÍZEMÍM I..png
BBA logo.jpeg

  • Acoustic floor (not included)L

  • Perimeter VCL membrane

  • Floor boards 22mm (Chipboard)

  • Timber structure 240x60/80@600mm

  • Insulation 120mm (Mineral)

  • Timber battens 40x60@600mm

  • Plasterboard 12.5mm (not included)

  • Plasterboard 12.5mm (not included)

  • 3mm skim (not included)

 


Construction Type  F2
Floor

SCHÉMA STROPU NAD PŘÍZEMÍM II..jpg
BBA logo.jpeg

  • Acoustic floor (not included)L

  • Perimeter VCL membrane

  • Floor boards 22mm (Chipboard)

  • Timber structure 240x60/80@600mm

  • Insulation 120mm (Mineral)

  • Metal frame 40x60@600mm

  • Plasterboard 12.5mm (not included)

  • Plasterboard 12.5mm (not included)

  • 3mm skim (not included)

 


Construction Type  C1
Ceiling

schema stropu nad podkrovim.png
BBA logo.jpeg

  • Attic insulation 120mm (Mineral)

  • Floor boards 22mm (Chipboard)

  • Timber structure 180x60/80@600mm

  • Insulation 180mm (Mineral)

  • VCL membrane

  • Timber battens 40x60@600mm

  • Plasterboard 12.5mm (not included)

  • 3mm skim (not included)

 


Construction Type  R1
Roof

Schéma ploché střešní konstrukce.jpg
BBA logo.jpeg

  • Weatherproof membrane (not included)

  • Flat roof insulation (not included)

  • Vapour control layer (not included)

  • Sarking boards 15mm

  • Timber structure 240x60/80@600mm

  • Insulation 50mm (Mineral)

  • VCL membrane

  • Timber battens 40x60@600mm

  • Plasterboard 12.5mm (not included)

  • Plasterboard 12.5mm (not included)

  • 3mm skim (not included)

 


Construction Type  R2
Roof

schema stresni konstrukce_M2020.jpg
BBA logo.jpeg

  • Roof tyles (not included)

  • Roof timber battens (not included)

  • Roof timber counter battens (not included)

  • Roof insulation (not included)

  • Sarking boards 15mm

  • Timber structure 180x60/80@600mm

  • Insulation 180mm (Mineral)

  • VCL membrane

  • Timber battens 40x60@600mm

  • Plasterboard 12.5mm (not included)

  • 3mm skim (not included)

 


Construction Type  R3
Roof

schema stresni konstrukce_M2020.jpg
BBA logo.jpeg

  • Roof tyles (not included)

  • Roof timber battens (not included)

  • Roof timber counter battens (not included)

  • Roof insulation (not included)

  • Sarking boards 15mm

  • Timber structure 180x60/80@600mm

  • Insulation 180mm (Mineral) (not included)

  • VCL membrane (not included)

  • Timber battens 40x60@600mm (not included)

  • Plasterboard 12.5mm (not included)

  • 3mm skim (not included)

 


UPVC Window

 

Untitled.png
UPVC window specification.png


UPVC HS Portal

 

HS.png
window specification HS.png


UPVC Door

 

DOOR.png
door specification.png


Aluminium Window

 

hlinik.png
hlinik spec.png


COMPONENTS
 

bottom of page